3" External S SEAL PR2 test witnessed by BV
JST 3" External S seal use material HNBR85+316SS, we verify the S seal at working condition -29°C to +121°C, 10000PSi, product design refer to API 6A -annex F.
Below are the external S seal main test contents:
• 1-Visual and dimension inspection for the seals and test fixture before the testing
• 2-Witness the seals assembling progress
• 3-Witness the sealing test for the O-ring from C port and D port at ambient temperature at 100psi
• 4-Witness the sealing test for 3" S-seals from B port at ambient temperature at 10000Psi
• 5-Witness the pressure and temperature cycling sealing test for 3” S-seal
• 6-Post-test examination after disassembling
Progress photos:
For the detailed content, welcome to contact us.