Recently, JST 13 inch External S seal has successfully passed the PR2 test at P-U (-20 deg F - 250 degrees F), 10000PSI nitrogen high pressure as per API 6A 21st Edition Annex F Section F.2.14: Design Verification for PR2F Group 5 Mandrel-type hangers, Table F.17 Sections: Pressure from below seals and pressure from above annulus seals. Test as specified in F.1.11 Test Procedure we follow as below...
JST 3" External S seal use material HNBR85+316SS, we verify the S seal at working condition -29°C to +121°C, 10000PSi, product design refer to API 6A -annex F. Below are the external S seal main test contents: • 1-Visual and dimension inspection for the seals and test fixture before the testing • 2-Witness the seals assembling progress • 3-Witness the sealing test for the O-ring from C port ...
JST 3" External S seal passed PR2 test, as well as 13” S seal. JST S seal use material HNBR85+316SS, BV witnessed HNBR S seal at working condition -29°C to +121°C, 10000PSi, product design refer to API 6A -annex F. The material HNBR(H3385) meet API immersion test, RGD test. The Inspector also applied following activities: 1: Reviewed the test certificate of raw material HNBR ( H3385), the Re...